780781

Coils and Transformers

TRANSFORMER,POWER

780781

5950-01-185-0646

5950 - Coils and Transformers

Hamilton Sundstrand Corporation

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    5 pin

  • Winding Operating Current

    20.0 milliamperes ac maximum single component single secondary

  • Winding Function And Quantity

    1 primary and 1 secondary single component

  • Mounting Method

    unthreaded hole single group

  • Mounting Facility Quantity

    2 single group

  • Inclosure Type

    fully inclosed

  • Input-Output Phase Relationship

    single phase to single phase single component

  • Winding Operating Voltage

    95.00 ac volts minimum and 122.00 ac volts maximum single component single prima

  • ~1

    ry

  • Winding Tap Location

    center tap single component single secondary

  • Distance Between Mounting Facility Centers

    1.365 inches minimum and 1.385 inches maximum single mounting facility single ce

  • ~1

    nter group

  • Frequency Rating

    380.0 hertz minimum and 420.0 hertz maximum single component

  • Mounting Hole Diameter

    0.114 inches nominal single group

  • Overall Width

    1.120 inches minimum and 1.200 inches maximum

  • Overall Height

    0.860 inches nominal

  • Overall Length

    1.720 inches nominal

  • Reliability Indicator

    not established

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products