6752-37-4
Circuit Breakers
CIRCUIT BREAKER
6752-37-4
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Body Width
0.760 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
4.0 amperes ac single location
-
Mounting Surface To Terminal End Distance
2.370 inches nominal
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.800 inches minimum and 1.820 inches maximum
-
Pole Quantity
1
-
Body Length
2.189 inches maximum
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Length
1.190 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Unpackaged Unit Weight
0.230 pounds
-
Case Material
plastic
-
Operating Voltage Type And Rating Per Pole In Volts
230.0 ac single location
-
Terminal Type And Quantity
2 tab w/screw
-
Inclosure Protection Type For Which Designed
explosion proof and corrosion resistant and sandtight and dustproof and humidity proof and fungus resistant
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Bushing Length
0.235 inches minimum and 0.250 inches maximum
-
Body Style
single pole type
-
Frequency In Hertz
400.0 single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct single location and 37.000 maximum at 200 pct single location
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods