Technical Characteristics
- 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
30.0 amperes ac resistive load
 - 
                                    
Terminal Type And Quantity
15 threaded stud all functions
 - 
                                    
Mounting Facility Type And Quantity
4 unthreaded hole single mounting facility
 - 
                                    
Nonpile-Up Auxiliary Contact Arrangement
1 pole, single throw, normally open, momentary action and 1 pole, single throw, normally closed, momentary action
 - 
                                    
Overall Height
2.790 inches nominal
 - 
                                    
Mounting Facility Pattern
rectangular single mounting facility
 - 
                                    
Overall Length
2.940 inches nominal
 - 
                                    
Time Delay
0.025 seconds maximum fixed operate and release time
 - 
                                    
Overall Width
1.900 inches nominal
 - 
                                    
Duty Type
continuous
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Environmental Protection
hermetic
 - 
                                    
Arc Quenching Method
air
 - 
                                    
Center To Center Distance Between Mounting Facilities Parallel To Width
1.063 inches nominal single mounting facility
 - 
                                    
Winding Quantity
1
 - 
                                    
Cubic Measure
15.585 cubic inches
 - 
                                    
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes dc resistive load
 - 
                                    
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
500.0 milliamperes dc lamp load
 - 
                                    
Case Material
metal
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac motor load
 - 
                                    
Features Provided
polarized
 - 
                                    
Center To Center Distance Between Mounting Facilities Parallel To Length
2.500 inches nominal single mounting facility
 - 
                                    
Nominal Operating Current Rating And Type
170.0 milliamperes dc single winding
 - 
                                    
Unthreaded Mounting Hole Diameter
0.193 inches nominal single mounting facility
 - 
                                    
Main Contact Maximum Voltage Rating In Volts
115.0 ac
 - 
                                    
Purpose For Which Designed
general
 - 
                                    
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
 - 
                                    
Nonpile-Up Main Contact Arrangement
3 pole, double throw, double break/double make, permanent jumper, one position momentary
 - 
                                    
Coil Quantity
1
 - 
                                    
Auxiliary Contact Maximum Voltage Rating In Volts
28.0 dc
 