AP14-1060-2
Circuit Breakers
CIRCUIT BREAKER
AP14-1060-2
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Internal Trip Release Configuration
relay trip second location
 - 
                                    
Pole Quantity
2
 - 
                                    
Reset Method
manual
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Trip Release Characteristic
time delay all locations
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
 - 
                                    
Nominal Thread Size
0.375 inches
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Arc Quenching Method
air
 - 
                                    
Bushing Length
0.380 inches maximum
 - 
                                    
Special Features
two 6-32 threaded holes; for added mounting stability
 - 
                                    
Thread Series Designator
unef
 - 
                                    
Body Width
1.250 inches maximum
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac all locations
 - 
                                    
Inclosure Protection Type For Which Designed
general purpose
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
0.375 inches nominal
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Actuator Position Designation
between pole one and two
 - 
                                    
Body Length
1.500 inches maximum
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations
 - 
                                    
Case Material
metal
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Internal Trip Release Configuration
series trip first location
 - 
                                    
Mounting Surface To Terminal End Distance
1.780 inches maximum
 - 
                                    
Trip Release Method
magnetic all locations
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    