AM3-A8-AB-3-10
Circuit Breakers
CIRCUIT BREAKER
AM3-A8-AB-3-10
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps5000.0 ac all locations 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts480.0 ac all locations 
- 
                                    Body Length2.490 inches minimum and 2.510 inches maximum 
- 
                                    Manual Actuator Type And Quantity3 toggle 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current40.000 minimum at 125 pct all locations and 500.000 maximum at 125 pct all locations 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.052 inches minimum and 2.072 inches maximum 
- 
                                    Boss Height0.130 inches minimum and 0.150 inches maximum 
- 
                                    Case Materialplastic 
- 
                                    Terminal Type And Quantity6 threaded stud 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Inclosure Protection Type For Which Designeddustproof 
- 
                                    Thread Series Designatorunc 
- 
                                    Reset Methodmanual 
- 
                                    Mounting Surface To Terminal End Distance2.461 inches minimum and 2.481 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.928 inches minimum and 1.948 inches maximum 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    End Item Identificationdesalinator,model sw100 onboard 110 ft coast guard vessels 
- 
                                    Body Width2.240 inches minimum and 2.251 inches maximum 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Maximum Continuous Load Current Rating Per Pole3.0 amperes ac all locations 
- 
                                    Mounting Facility Type And Quantity6 threaded hole 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Frequency In Hertz60.0 all locations 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    