Technical Characteristics

  • Mounting Surface To Terminal End Distance

    2.260 inches nominal

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Body Style

    single pole type

  • Bushing Length

    0.390 inches nominal

  • Thread Quantity Per Inch

    27

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Frequency In Hertz

    60.0 single location

  • Body Width

    0.570 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 28.0 dc single location

  • Body Length

    1.140 inches nominal

  • Unpackaged Unit Weight

    0.062 pounds

  • Terminal Type And Quantity

    4 quick disconnect, male

  • Center To Center Distance Between Terminals Parallel To Length

    0.780 inches nominal

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Actuator Function

    reset

  • Fragility Factor

    moderately rugged

  • Reset Method

    manual

  • Internal Trip Release Configuration

    relay trip single location

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    400.0 ac single location and 400.0 dc single location

  • Manual Actuator Type And Quantity

    1 push button

  • Nominal Thread Size

    0.375 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Characteristic

    time delay single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...