M39016/6-214M
Relays and Solenoids
RELAY,ELECTROMAGNETIC
M39016/6-214M
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performanc
-
Test Data Document
81349-mil-r-39016 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Fragility Factor
moderately rugged
-
Specification/Standard Data
81349-mil-r-39016/6 government specification
-
Storage Type
general purpose warehouse
-
Criticality Code Justification
feat
-
Overall Width
0.410 inches maximum
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Overall Height
0.600 inches maximum
-
Cubic Measure
0.325 cubic inches
-
Mounting Facility Pattern
in-line single mounting facility
-
Overall Length
1.320 inches maximum
-
Mounting Slot Width
0.120 inches nominal single mounting facility
-
Duty Type
continuous
-
Operating Voltage Rating And Type At Specified Temp
12.0 volts dc 25 deg celsius single winding
-
Coil Quantity
1
-
Purpose For Which Designed
general
-
Main Contact Load Current Rating At Maximum Rated Voltage
160.0 milliamperes dc lamp load
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
300.0 milliamperes ac resistive load and 2.0 amperes dc resistive load
-
Terminal Type And Quantity
8 wire hook all functions
-
Special Features
failure rate level 0.1 percent
-
Features Provided
polarized
-
Case Material
metal
-
Winding Quantity
1
-
Mounting Facility Type And Quantity
2 slotted hole single mounting facility
-
Winding Dc Resistance Rating
160.0 ohms nominal single winding
-
Arc Quenching Method
air
-
Time Delay
0.004 seconds maximum fixed operate and release time
-
Environmental Protection
hermetic
-
Main Contact Load Current Rating At Maximum Rated Voltage
750.0 milliamperes dc inductive load
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.062 inches minimum single mounting facility and 1.078 inches maximum single mounting facility
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods