M5757/90-003
Relays and Solenoids
RELAY,ELECTROMAGNETIC
M5757/90-003
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-r-39016 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Terminal Type And Quantity
14 wire hook all functions
-
Duty Type
continuous
-
Special Features
failure rate level 1.0
-
Time Delay
0.005 seconds maximum fixed operate and release time
-
Main Contact Load Current Rating At Maximum Rated Voltage
200.0 milliamperes dc lamp load
-
Coil Quantity
1
-
Environmental Protection
hermetic and shock resistant and vibration resistant
-
Nonpile-Up Main Contact Arrangement
4 pole, double throw, one position momentary
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
300.0 milliamperes ac resistive load and 2.0 amperes dc resistive load
-
Specification/Standard Data
81349-mil-r-39016/40 government specification
-
Mounting Facility Type And Quantity
1 terminal single mounting facility
-
Overall Length
1.310 inches nominal
-
Winding Quantity
1
-
Operating Voltage Rating And Type At Specified Temp
26.5 volts dc 25 deg celsius single winding
-
Overall Width
0.480 inches nominal
-
Criticality Code Justification
feat
-
Winding Dc Resistance Rating
390.0 ohms nominal single winding
-
Overall Height
0.390 inches nominal
-
~1
data on certain environmental and performanc
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods