M6106/29-032U
Relays and Solenoids
RELAY,ELECTROMAGNETIC
M6106/29-032U
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
-
~1
data on certain environmental and performance
-
Specification/Standard Data
81349-mil-r-6106/29 government specification
-
Terminal Type And Quantity
11 wire hook all functions
-
Case Material
metal
-
Mounting Facility Type And Quantity
4 slotted hole single mounting facility
-
Winding Quantity
1
-
Arc Quenching Method
air
-
Environmental Protection
hermetic
-
Time Delay
0.006 seconds maximum fixed operate and release time
-
Criticality Code Justification
feat
-
Storage Type
general purpose warehouse
-
Overall Height
0.810 inches maximum
-
Mounting Facility Pattern
rectangular single mounting facility
-
Mounting Slot Width
0.133 inches nominal single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
-
Fragility Factor
moderately rugged
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.078 inches nominal single mounting facility
-
Duty Type
continuous
-
Winding Dc Resistance Rating
400.0 ohms nominal single winding
-
Nonpile-Up Main Contact Arrangement
3 pole, double throw, one position momentary
-
End Item Identification
hoist rescue
-
Cubic Measure
0.663 cubic inches
-
Overall Width
0.640 inches maximum
-
Coil Quantity
1
-
Overall Length
1.280 inches maximum
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
-
Purpose For Which Designed
general
-
Main Contact Load Current Rating At Maximum Rated Voltage
6.0 amperes dc inductive load
-
Special Features
failure rate level 0.5 percent
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.405 inches nominal single mounting facility
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods