EP-434
Relays and Solenoids
RELAY,ELECTROMAGNETIC
EP-434
Leach International Corporation
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Nonpile-Up Main Contact Arrangement
1 pole, single throw, normally open, momentary action and 3 pole, double throw, one position momentary
 - 
                                    
Coil Quantity
1
 - 
                                    
Operating Voltage Rating And Type At Specified Temp
230.0 volts ac 25 deg celsius single winding
 - 
                                    
Test Data Document
94756-455-0652 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac motor load and 2.0 amperes dc motor load
 - 
                                    
Duty Type
continuous
 - 
                                    
Center To Center Distance Between Mounting Facilities Parallel To Width
0.625 inches nominal single mounting facility
 - 
                                    
Overall Width
1.025 inches maximum
 - 
                                    
Cubic Measure
3.170 cubic inches
 - 
                                    
End Item Identification
b-1b
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac inductive load and 4.0 amperes dc inductive load
 - 
                                    
Time Delay
0.024 seconds maximum fixed operate time
 - 
                                    
Mounting Facility Pattern
triangle single mounting facility
 - 
                                    
Main Contact Maximum Voltage Rating In Volts
230.0 ac and 28.0 dc
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
 - 
                                    
Frequency In Hertz
400.0 nominal
 - 
                                    
Case Material
metal
 - 
                                    
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
1.396 inches minimum single mounting facility and 1.446 inches maximum single mounting facility
 - 
                                    
Mounting Facility Type And Quantity
3 slotted hole single mounting facility
 - 
                                    
Special Features
nuclear hardness critical item
 - 
                                    
Overall Height
1.800 inches maximum
 - 
                                    
Overall Length
1.718 inches maximum
 - 
                                    
Winding Quantity
1
 - 
                                    
Arc Quenching Method
air
 - 
                                    
Mounting Slot Width
0.150 inches nominal single mounting facility
 - 
                                    
Environmental Protection
hermetic
 - 
                                    
Purpose For Which Designed
specific
 - 
                                    
Time Delay
0.0475 seconds maximum fixed release time
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac resistive load and 5.0 amperes dc resistive load
 - 
                                    
Criticality Code Justification
feat
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Terminal Type And Quantity
16 pin all functions
 - 
                                    
Fragility Factor
moderately rugged
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    