AQB-A250-125N
Circuit Breakers
CIRCUIT BREAKER
AQB-A250-125N
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
11.000 inches maximum
-
Manual Actuator Type And Quantity
1 toggle
-
Thread Quantity Per Inch
20
-
Frequency In Hertz
60.0 all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.000 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Precious Material And Location
contact surfaces silver
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
20000.0 ac all locations and 15000.0 dc all locations
-
Inclosure Protection Type For Which Designed
general purpose
-
Special Features
mounting hardware included
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud
-
Fragility Factor
moderately rugged
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
9.875 inches nominal
-
Trip Release Characteristic
instantaneous all locations
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Reset Method
manual
-
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac all locations and 250.0 dc all locations
-
Center To Center Distance Between Terminals Parallel To Length
9.875 inches nominal
-
Precious Material
silver
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Boss Height
0.063 inches nominal
-
Mounting Facility Type And Quantity
4 threaded hole
-
Body Width
9.000 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
3.000 inches nominal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Release Method
thermal-magnetic all locations
-
Actuator Position Designation
at pole two
-
Trip Release Ambient Temp Rating
50.0 deg celsius nominal all locations
-
Body Style
multipole-single actuator type
-
Specification/Standard Data
81349-mil-c-17361 government specification
-
Test Data Document
81349-mil-c-17361 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Maximum Continuous Load Current Rating Per Pole
250.0 amperes ac all locations
-
Nominal Thread Size
0.250 inches
-
Mounting Surface To Terminal End Distance
9.218 inches maximum
-
~1
data on certain environmental and performanc
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods




