351422-10
Switches
SWITCH,THERMOSTATIC
351422-10
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
1.830 inches nominal
-
Temp Sensing Element Type
capillary tube-bulb
-
Bulb Diameter
0.190 inches nominal
-
Contact Adjustability
actuation point not adjustable
-
Distance Between Mounting Facility Centers
1.209 inches minimum and 1.229 inches maximum
-
Criticality Code Justification
feat
-
Special Features
weapon system essential
-
Contact Load Current Rating
25.0 amperes resistive load single voltage
-
Thread Quantity Per Inch
32 all threaded hole
-
Bulb Length
10.000 inches minimum and 12.000 inches maximum
-
Capillary Tube Length
72.0 inches nominal
-
Thread Class
2b all threaded hole
-
Contact Voltage Rating In Volts
250.0 ac at sea level single voltage
-
Thread Series Designator
unc all threaded hole
-
Nominal Thread Size
0.164 inches all threaded hole
-
Media For Which Designed
gas or liquid
-
Body Height
2.880 inches nominal
-
Contact Stimulus Rating
159.00 actuation point minimum degrees fahrenheit and 179.00 actuation point maximum degrees fahrenheit
-
Overall Width
2.432 inches nominal
-
Mounting Method
bracket and threaded hole
-
Mounting Facility Pattern
two position in-line
-
End Item Identification
kidd class ddg, tarawa class lha, forrestal class cv, ticonderoga class cg (47), wasp class lhd, spruance class dd (963), nimitz class cvn, oliver perry class ffg, los angeles class ssn (688).
-
Contact Action Stimulus
increase