AP-6-IRC-5-1-302
Circuit Breakers
CIRCUIT BREAKER
AP-6-IRC-5-1-302
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Body Style
2a single pole type
 - 
                                    
Bushing Length
0.380 inches maximum
 - 
                                    
Body Length
1.500 inches maximum
 - 
                                    
Pole Quantity
1
 - 
                                    
Iii Arc Quenching Method
magnetic blowout
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc single location
 - 
                                    
Thread Series Designator
unef
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
200.0 single location
 - 
                                    
Reset Method
manual
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Auxiliary Switch Function And Quantity
1 alarm
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 maximum at 200 pct single location
 - 
                                    
Switch Current Rating And Type In Amps
0.5 dc
 - 
                                    
Switch Voltage Rating And Type In Volts
50.0 dc
 - 
                                    
Iii Unpackaged Unit Weight
1.800 ounces
 - 
                                    
Terminal Type And Quantity
2 screw
 - 
                                    
Body Width
0.625 inches maximum
 - 
                                    
Case Material
plastic
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
 - 
                                    
Switch Contact Arrangement
single pole, single throw, normally closed
 - 
                                    
Iii Fragility Factor
moderately rugged
 - 
                                    
Mounting Surface To Terminal End Distance
1.750 inches maximum
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing
 - 
                                    
Iii Storage Type
general purpose warehouse
 - 
                                    
Iii Special Handling Feature
magnetic
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Trip Release Method
magnetic single location
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Internal Trip Release Configuration
series trip w/auxiliary load terminal single location
 - 
                                    
Nominal Thread Size
0.375 inches
 - 
                                    
Switch Location And Position Designation
internal at pole one
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.090 minimum at 200 pct and
 - 
                                    
Inclosure Protection Type For Which Designed
hermetically sealed
 - 
                                    
Switch Terminal Type
wire hook
 - 
                                    
Switch Voltage Rating And Type In Volts
120.0 ac and
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    