Technical Characteristics

  • ~1

    data on certain environmental and performanc

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Switch Location And Position Designation

    internal at pole two

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Nonturn Device Width

    0.138 inches nominal

  • Nonturn Device Location

    at 12 oclock

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Specification/Standard Data

    81349-mil-c-39019/4 government specification

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations

  • Body Width

    1.281 inches maximum

  • Switch Terminal Type

    solder stud

  • Features Provided

    high inrush protection

  • Special Features

    mounting hardware included

  • Case Material

    plastic

  • Internal Trip Release Configuration

    series trip w/auxiliary load terminal all locations

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Body Length

    1.562 inches maximum

  • Test Data Document

    81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    200.0 all locations

  • Fragility Factor

    moderately rugged

  • Nonturn Device Diameter

    0.250 inches nominal

  • Bushing Length

    0.380 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations and 2.0 amperes dc all locations

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Terminal Type And Quantity

    4 wire hook

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Nonturn Device Length

    0.280 inches nominal

  • Body Style

    multipole-single actuator type

  • Nonturn Device Radius

    0.625 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations or 400.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Thread Series Designator

    unef

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Switch Contact Arrangement

    double pole, double throw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...