W28X-Q1A-5
Circuit Breakers
CIRCUIT BREAKER
W28X-Q1A-5
Potter And Brumfield Div Amf Canada
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Actuator Functionreset 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Mounting Facility Type And Quantity2 clip 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Body Stylerectangular dimensional envelope 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac single location and 1000.0 dc single location 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Manual Actuator Type And Quantity1 push button 
- 
                                    Overall Height0.760 inches maximum 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Overall Width0.760 inches maximum 
- 
                                    Trip Release Methodthermal single location 
- 
                                    Arc Quenching Methodair 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent135.0 single location 
- 
                                    Pole Quantity1 
- 
                                    Unpackaged Unit Weight0.350 ounces 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac single location and 5.0 amperes dc single location 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Frequency In Hertz50.0 single location or 60.0 single location 
- 
                                    Inclosure Protection Type For Which Designedgeneral purpose 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current2.200 minimum at 200 pct single location and 15.000 maximum at 200 pct single location 
- 
                                    Terminal Type And Quantity2 quick disconnect, male 
- 
                                    Overall Length1.535 inches maximum 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac single location and 32.0 dc single location 
- 
                                    Case Materialplastic 
- 
                                    Reset Methodmanual 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    