10767700

Circuit Breakers

CIRCUIT BREAKER

10767700

5925-01-239-9656

5925 - Circuit Breakers

Henley Marine Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Unpackaged Unit Weight

    2.200 ounces

  • Arc Quenching Method

    magnetic blowout

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Terminal Type And Quantity

    2 tab, solder lug

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Switch Terminal Type

    pin

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Inclosure Protection Type For Which Designed

    corrosion resistant and moisture resistant and shockproof and vibrationproof

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.515 inches minimum and 1.545 inches maximum

  • Thread Series Designator

    unc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Boss Height

    0.115 inches minimum and 0.145 inches maximum

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct single location and 3.000 maximum at 200 pct single location

  • Circuit Protection Type

    overcurrent single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.645 inches minimum and 1.675 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...