447-0309-003
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
447-0309-003
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Style Designator
rectangular terminal/terminals on two surfaces
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Operating Current Rating Per Function In Amps
8.0 2nd radio interference
-
Functional Terminal Type And Quantity
1 threaded stud ground 3rd function
-
Special Features
two unfiltered functions
-
Overall Height
2.220 inches minimum and 2.280 inches maximum
-
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at sea level
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Body Length
4.470 inches minimum and 4.530 inches maximum
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.164 inches
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Features Provided
moisture resistant and shock resistant
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Operating Temp Range
+0.0/+75.0 deg celsius
-
Functional Terminal Type And Quantity
2 threaded stud input 1st function
-
Maximum Voltage Drop Per Function
1.3 volts ac 1st radio interference
-
Body Width
2.350 inches minimum and 2.410 inches maximum
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Unpackaged Unit Weight
2.000 pounds
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Body Height
1.470 inches minimum and 1.530 inches maximum
-
Maximum Temp Rise
25.0 deg celsius
-
Inclosure Type
encased
-
Overall Length
5.330 inches minimum and 5.420 inches maximum
-
Operating Current Rating Per Function In Amps
8.0 1st radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Functional Terminal Type And Quantity
2 threaded stud output 2nd function
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
-
Mounting Facility Type And Quantity
4 threaded hole
-
Body Material
metal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Maximum Voltage Drop Per Function
1.3 volts dc 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.985 inches minimum and 4.015 inches maximum
Related Parts by Category