5028651

Circuit Breakers

CIRCUIT BREAKER

5028651

5925-01-245-4643

5925 - Circuit Breakers

Us Army Combat Surveillance And

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unc

  • Internal Trip Release Configuration

    series trip second location

  • Internal Trip Release Configuration

    series trip first location

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Features Provided

    high inrush protection

  • Boss Height

    0.220 inches nominal

  • End Item Identification

    6660-01-148-1772

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Case Material

    plastic

  • Body Style

    8c multipole-multiple actuator type

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Pole Quantity

    3

  • Mounting Surface To Terminal End Distance

    3.550 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    3.550 inches nominal

  • Body Width

    3.105 inches maximum

  • Body Length

    5.125 inches nominal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    relay trip third location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 10.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Frequency In Hertz

    47.0 or 63.0

  • Terminal Type And Quantity

    8 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...