MIL-PRF-6106
Relays and Solenoids
RELAY,ELECTROMAGNETIC
MIL-PRF-6106
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Fragility Factor
moderately rugged
-
Nominal Operating Current Rating And Type
110.0 milliamperes dc single winding
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
-
Storage Type
general purpose warehouse
-
Criticality Code Justification
feat
-
Time Delay
0.01 seconds maximum fixed operate and release time
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Environmental Protection
hermetic
-
Mounting Slot Width
0.150 inches nominal single mounting facility
-
Winding Dc Resistance Rating
320.0 ohms nominal single winding
-
End Item Identification
4935012075355 test station,guided
-
Arc Quenching Method
air
-
Mounting Facility Type And Quantity
2 slotted hole single mounting facility
-
Winding Quantity
1
-
Overall Length
1.718 inches maximum
-
Case Material
metal
-
Features Provided
polarized
-
Cubic Measure
1.191 cubic inches
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
-
Terminal Type And Quantity
8 wire hook all functions
-
Overall Height
1.320 inches maximum
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Specification/Standard Data
96906-ms27401 government standard
-
Overall Width
0.525 inches maximum
-
Purpose For Which Designed
general
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
-
Coil Quantity
1
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.396 inches minimum single mounting facility and 1.446 inches maximum single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes ac inductive load and 8.0 amperes dc inductive load
-
Duty Type
continuous
-
Mounting Facility Pattern
in-line single mounting facility
-
Special Features
failure rate level 1.0 percent
-
~1
data on certain environmental and performance
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods