Technical Characteristics
-
Switch Contact Arrangement
single pole, double throw
-
Switch Current Rating And Type In Amps
10.0 ac and 3.0 dc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Mounting Facility Type And Quantity
6 threaded hole
-
Body Style
multipole-single actuator type
-
Unpackaged Unit Weight
6.600 ounces
-
Body Width
2.265 inches maximum
-
Manual Actuator Type And Quantity
1 toggle
-
Nominal Thread Size
0.138 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
-
Special Features
black handle without markings
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Terminal Type And Quantity
6 screw
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Inclosure Protection Type For Which Designed
moisture resistant and salt spray proof and shock resistant and vibration resistant
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Auxiliary Switch Function And Quantity
1 alarm
-
Case Material
plastic
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Mounting Surface To Terminal End Distance
2.032 inches maximum
-
Thread Quantity Per Inch
32
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.645 inches minimum and 1.675 inches maximum
-
Actuator Position Designation
at pole two
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.515 inches minimum and 1.545 inches maximum
-
Thread Series Designator
unc
-
Reset Method
manual
-
Switch Location And Position Designation
internal at pole three
-
Boss Height
0.115 inches minimum and 0.145 inches maximum
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods