M55629/6-244

Circuit Breakers

CIRCUIT BREAKER

M55629/6-244

5925-01-265-7737

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Case Material

    plastic

  • Body Length

    2.510 inches maximum

  • Body Style

    8c multipole-multiple actuator type

  • Specification/Standard Data

    81349-mil-c-55629/6 government specification

  • Terminal Type And Quantity

    6 threaded stud

  • Thread Series Designator

    unc

  • Test Data Document

    81349-mil-c-55629 specification

  • Frequency In Hertz

    400.0

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Trip Release Characteristic

    time delay all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    3 threaded hole

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    3

  • Mounting Surface To Terminal End Distance

    2.800 inches maximum

  • Boss Height

    0.109 inches minimum and 0.171 inches maximum

  • Fragility Factor

    moderately rugged

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Body Width

    2.205 inches minimum and 2.285 inches maximum

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.0 dc

  • Switch Terminal Type

    tab, solder lug

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 10.000 maximum at 200 pct all locations

  • Switch Location And Position Designation

    internal at pole one

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Manual Actuator Type And Quantity

    3 toggle

  • Reset Method

    manual

  • Trip Release Method

    magnetic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.719 inches minimum and 0.781 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...