MSBJ105079

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

MSBJ105079

5915-01-265-9357

5915 - Filters and Networks

Itt Cannon Electric

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Length

    2.030 inches nominal

  • Body Outside Diameter

    1.625 inches nominal

  • Iii Vibration Resistance Range In Hertz

    10.0 to 500.0

  • Iii Operating Temp Range

    -55.0 to 85.0 deg celsius

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Operating Current Rating Per Function In Amps

    20.0 1st radio interference

  • Operating Current Rating Per Function In Amps

    20.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    20.0 4th radio interference

  • Operating Current Rating Per Function In Amps

    20.0 5th radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 3rd radio interference and 2.0 volts dc 3rd radio interference

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Iii Input Terminal Manufacturer Code

    94756

  • Iii Output Terminal Manufacturer Code

    94756

  • Iii Full Load Minimum Insertion Loss At Specified Frequency In Decibels

    3.0 and 15.0 and 20.0 and 35.0 and 50.0 and 50.0

  • Inclosure Type

    hermetically sealed

  • Mounting Facility Type And Quantity

    1 unthreaded hole

  • Features Provided

    shock resistant

  • Functional Terminal Type And Quantity

    18 friction w/grounding strap and pin input-output

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 1st radio interference and 200.0 volts dc 1st radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 2nd radio interference and 200.0 volts dc 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 3rd radio interference and 200.0 volts dc 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 4th radio interference and 200.0 volts dc 4th radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 5th radio interference and 200.0 volts dc 5th radio interference

  • Iii Body Material

    metal

  • Iii Maximum Dielectric Withstanding Dc Voltage

    500.0 volts at sea level

  • Iii Body Surface Treatment

    cadmium

  • Style Designator

    26 round terminal/terminals on opposite surfaces

  • Unthreaded Mounting Hole Diameter

    0.187 inches nominal

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Operating Current Rating Per Function In Amps

    20.0 2nd radio interference

  • Operating Current Rating Per Function In Amps

    20.0 6th radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 1st radio interference and 2.0 volts dc 1st radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 2nd radio interference and 2.0 volts dc 2nd radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 4th radio interference and 2.0 volts dc 4th radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 5th radio interference and 2.0 volts dc 5th radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 6th radio interference and 2.0 volts dc 6th radio interference

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Iii Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Iii Input Terminal Identification

    ms3108e18-1p

  • Iii Output Terminal Identification

    ms3102e18-1s

  • Iii Maximum Temp Rise

    25.0 deg celsius

  • Iii Full Load Insertion Loss Frequencies In Megahertz

    0.1 and 1.0 and 2.0 and 10.0 and 100.0 and 1000.0

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 6th radio interference and 200.0 volts dc 6th radio interference

  • Criticality Code Justification

    feat

  • Special Features

    nuclear hardness critical item

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...