ASC1498733

Circuit Breakers

CIRCUIT BREAKER

ASC1498733

5925-01-266-0837

5925 - Circuit Breakers

Asc Pty Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.700 minimum at 200 pct single location and 10.000 maximum at 200 pct single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    3.0 millimeters

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Thread Pitch In Millimeters

    0.50

  • Inclosure Protection Type For Which Designed

    salt water resistant and moisture resistant and shock resistant and vibration resistant

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc single location

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

  • Thread Series Designator

    iso m

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Body Width

    0.750 inches maximum

  • Unpackaged Unit Weight

    3.700 ounces

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc single location

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Special Handling Feature

    magnetic

  • Reset Method

    manual

  • Boss Height

    0.150 inches nominal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Mounting Facility Type And Quantity

    2 threaded hole

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...