BR160
Circuit Breakers
CIRCUIT BREAKER
BR160
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
 - 
                                    
Inclosure Protection Type For Which Designed
dustproof
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Arc Quenching Method
air
 - 
                                    
Pole Quantity
1
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Mounting Facility Type And Quantity
2 terminal
 - 
                                    
Frequency In Hertz
60.0 single location
 - 
                                    
Terminal Type And Quantity
2 clip
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac single location
 - 
                                    
Case Material
plastic
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
60.0 amperes ac single location
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    


