M55629/20NM

Circuit Breakers

CIRCUIT BREAKER

M55629/20NM

5925-01-267-1052

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Bushing Length

    0.464 inches minimum and 0.526 inches maximum

  • Nonturn Device Length

    0.115 inches minimum and 0.145 inches maximum

  • Thread Series Designator

    un

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Length

    1.969 inches minimum and 2.031 inches maximum

  • Frequency In Hertz

    60.0 single location

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Nonturn Device Radius

    0.641 inches minimum and 0.671 inches maximum

  • Body Style

    single pole type

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Nominal Thread Size

    0.500 inches

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Special Handling Feature

    magnetic

  • Switch Terminal Type

    tab, solder lug

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Center To Center Distance Between Terminals Parallel To Length

    1.499 inches minimum and 1.561 inches maximum

  • Pole Quantity

    1

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Specification/Standard Data

    81349-mil-c-55629/20 government specification

  • Thread Quantity Per Inch

    32

  • Nonturn Device Location

    at 12 oclock

  • Nonturn Device Diameter

    0.138 inches nominal

  • ~1

    data on certain environmental and performanc

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...