441 4024
Circuit Breakers
CIRCUIT BREAKER
441 4024
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Case Material
plastic
 - 
                                    
Thread Series Designator
uns
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 50.0 dc single location
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct single location and 40.000 maximum at 200 pct single location
 - 
                                    
Nominal Thread Size
0.469 inches
 - 
                                    
Body Width
0.560 inches nominal
 - 
                                    
End Item Identification
3810-01-165-0647
 - 
                                    
Terminal Type And Quantity
2 tab w/screw
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location and 10.0 amperes dc single location
 - 
                                    
Body Style
single pole type
 - 
                                    
Frequency In Hertz
400.0 single location
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.840 inches nominal
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Bushing Length
0.300 inches nominal
 - 
                                    
Pole Quantity
1
 - 
                                    
Inclosure Protection Type For Which Designed
fungus resistant
 - 
                                    
Mounting Surface To Terminal End Distance
1.660 inches nominal
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing
 - 
                                    
Trip Release Method
thermal single location
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Body Length
1.380 inches nominal
 - 
                                    
Manual Actuator Type And Quantity
1 push button
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 1000.0 dc single location
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Function
reset
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    