AP-1-1-65F-601

Circuit Breakers

CIRCUIT BREAKER

AP-1-1-65F-601

5925-01-273-2970

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Bushing Length

    0.380 inches maximum

  • Body Length

    1.562 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and 0.906 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Body Style

    2a single pole type

  • Body Width

    0.625 inches maximum

  • Case Material

    metal

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    600.0 milliamperes ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Frequency In Hertz

    60.0 single location

  • Unpackaged Unit Weight

    1.800 ounces

  • Terminal Type And Quantity

    2 wire hook

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.375 inches

  • Inclosure Protection Type For Which Designed

    hermetically sealed and and

  • Thread Series Designator

    unef

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.