308218-1
Coils and Transformers
TRANSFORMER,PULSE
308218-1
TRANSFORMER,PULSE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Dc Resistance Rating In Ohms
0.600 single component 1st secondary
-
Peak Voltage Rating (Non-Core)
28.0 volts single component single primary
-
Dc Resistance Rating In Ohms
0.050 single component 2nd secondary
-
Frequency Rating
50.0 kilohertz nominal single component
-
Dc Resistance Rating In Ohms
0.022 single component single primary
-
Winding Operating Current
45.0 milliamperes maximum of standard range b single component 1st secondary
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Inclosure Type
fully inclosed
-
Body Height
1.200 inches maximum
-
End Item Identification
5895-01-205-0643 time standard reference
-
Overall Height
1.640 inches maximum
-
Terminal Type And Quantity
9 pin
-
Reliability Indicator
not established
-
Mounting Method
terminal single group
-
Winding Tap Location (Non-Core)
center tap single component all secondary
-
Body Width
1.370 inches maximum
-
Maximum Operating Temp
130.0 deg celsius
-
Peak Voltage Rating (Non-Core)
12.0 volts single component 1st secondary
-
Peak Voltage Rating (Non-Core)
28.0 volts single component 2nd secondary
-
Winding Tap Location (Non-Core)
center tap single component single primary
-
Body Length
1.520 inches maximum
-
Primary To Secondary Turn Ratio
1 to 1 to 2 single component
-
Winding Operating Current
3.5 amperes maximum of standard range b single component 2nd secondary
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods