CD3-A3-DU-100-240-1
Circuit Breakers
CIRCUIT BREAKER
CD3-A3-DU-100-240-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Criticality Code Justification
feat
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations and 100.0 amperes dc all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.735 inches minimum and 2.765 inches maximum
-
Thread Quantity Per Inch
32
-
Special Features
back mount only
-
Center To Center Distance Between Terminals Parallel To Length
3.535 inches minimum and 3.565 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Mounting Facility Type And Quantity
6 threaded hole
-
Center To Center Distance Between Terminals Parallel To Width
1.011 inches minimum and 1.041 inches maximum
-
Nominal Thread Size
0.138 inches
-
Body Length
5.110 inches minimum and 5.130 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct all locations and 120.000 maximum at 200 pct all locations
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 125.0 dc all locations
-
Mounting Surface To Terminal End Distance
2.535 inches minimum and 3.565 inches maximum
-
Manual Actuator Type And Quantity
3 toggle
-
Body Width
3.093 inches minimum and 3.108 inches maximum
-
Unpackaged Unit Weight
2.000 pounds
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.011 inches minimum and 1.041 inches maximum
-
Features Provided
high inrush protection
-
Boss Height
0.205 inches minimum and 0.235 inches maximum
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations and 5000.0 dc all locations
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods