APGN-662-22005-2

Circuit Breakers

CIRCUIT BREAKER

APGN-662-22005-2

5925-01-281-6504

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Terminal Type And Quantity

    6 tab, solder lug

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    115.0 ac nominal first location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal and 6 threaded hole

  • Thread Quantity Per Inch

    32

  • Internal Trip Release Configuration

    series/relay trip first location

  • Trip Release Method

    magnetic-hydraulic all locations

  • Actuator Position Designation

    at pole two

  • Special Features

    relay coil ta pole one is instantanious trip

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Body Style

    multipole-single actuator type

  • Nonturn Device Location

    at 3 oclock and at 9 oclock and at 12 oclock

  • Internal Trip Release Configuration

    series trip second location

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Width

    2.250 inches nominal

  • Internal Trip Release Configuration

    series trip third location

  • Bushing Length

    0.625 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.651 inches minimum and 0.661 inches maximum

  • Trip Release Duty Cycle

    continuous first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations

  • Inclosure Protection Type For Which Designed

    moisture resistant and corrosion resistant and shockproof and vibrationproof

  • Nonturn Device Radius

    0.656 inches nominal

  • Unpackaged Unit Weight

    9.000 ounces

  • Case Material

    plastic

  • Nonturn Device Length

    0.130 inches nominal

  • Fragility Factor

    moderately rugged

  • Nominal Thread Size

    0.500 inches and 0.138 inches

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...