XJL434125
Circuit Breakers
CIRCUIT BREAKER
XJL434125
Challenger Electrical Equipment Corp
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Trip Release Characteristic
instantaneous all locations
 - 
                                    
Pole Quantity
3
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Body Style
rectangular dimensional envelope
 - 
                                    
Adjustable Trip Setting Current Range Per Pole In Amps
+625.0/+1250.0 ac all locations
 - 
                                    
Reset Method
manual
 - 
                                    
Features Provided
adjustable trip release
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Trip Release Ambient Temp Rating
40.0 deg celsius nominal all locations
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Unthreaded Mounting Hole Diameter
0.250 inches nominal
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
125.0 amperes ac all locations
 - 
                                    
Trip Release Method
thermal-magnetic all locations
 - 
                                    
Actuator Position Designation
at pole two
 - 
                                    
Inclosure Protection Type For Which Designed
fungus resistant
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
150000.0 ac all locations
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Terminal Type And Quantity
6 compression
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Mounting Facility Type And Quantity
4 unthreaded hole
 - 
                                    
Overall Length
17.125 inches nominal
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Overall Height
3.875 inches nominal
 - 
                                    
Overall Width
8.250 inches nominal
 - 
                                    
Special Features
includes fuses and fuse holder
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations
 - 
                                    
Case Material
plastic
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    