AS58091
Circuit Breakers
CIRCUIT BREAKER
AS58091
Society Of Automotive Engineers Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Specification/Standard Data96906-ms26574 government standard 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps2000.0 ac all locations and 2000.0 dc all locations 
- 
                                    Body Length0.780 inches nominal 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Terminal Type And Quantity2 screw 
- 
                                    Mounting Surface To Terminal End Distance1.525 inches nominal 
- 
                                    Trip Release Ambient Temp Rating71.0 deg fahrenheit maximum all locations 
- 
                                    Circuit Protection Typeovervoltage all locations 
- 
                                    Case Materialmetal 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent130.0 all locations 
- 
                                    Bushing Length0.250 inches nominal 
- 
                                    Body Width0.593 inches nominal 
- 
                                    Maximum Continuous Load Current Rating Per Pole20.0 amperes dc all locations 
- 
                                    Reset Methodmanual 
- 
                                    Body Stylesingle pole type 
- 
                                    Mounting Facility Type And Quantity2 terminal 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current3600.000 nominal at 130 pct all locations 
- 
                                    Frequency In Hertz380.0 all locations or 420.0 all locations 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts115.0 ac all locations and 28.0 dc all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.593 inches nominal 
- 
                                    Trip Release Methodthermal all locations 
- 
                                    Pole Quantity4 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    