APGH-66-1REC3-43-701-A-00
Circuit Breakers
CIRCUIT BREAKER
APGH-66-1REC3-43-701-A-00
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
1.515 inches maximum
-
Thread Series Designator
iso m
-
Auxiliary Switch Function And Quantity
1 alarm
-
Switch Terminal Type
quick disconnect, male
-
External Actuator Linkage Arrangement
one and two linked
-
Case Material
plastic
-
Boss Height
0.130 inches nominal
-
Switch Current Rating And Type In Amps
10.0 ac and 5.0 dc
-
Arc Quenching Method
magnetic blowout
-
Thread Pitch In Millimeters
0.50
-
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
-
Manual Actuator Type And Quantity
2 toggle
-
Frequency In Hertz
400.0 all locations
-
Terminal Type And Quantity
4 tab w/screw
-
Mounting Facility Type And Quantity
4 threaded hole
-
Mounting Surface To Terminal End Distance
2.032 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Switch Contact Arrangement
single pole, double throw
-
Special Features
toggle black without markings
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2100.0 ac all locations
-
Nominal Thread Size
3.0 millimeters
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
-
Unpackaged Unit Weight
4.400 ounces
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Switch Location And Position Designation
internal at pole two
-
Inclosure Protection Type For Which Designed
salt spray proof and moisture resistant and shock resistant and vibration resistant
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Continuous Load Current Rating Per Pole
700.0 milliamperes ac all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
12.000 minimum at 200 pct all locations and 120.000 maximum at 200 pct all locations
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods