050-005338-001
Coils and Transformers
TRANSFORMER,POWER
050-005338-001
Northrop Grumman Systems Corporation
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Rating
40.0 kilohertz nominal single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Inclosure Type
fully inclosed
-
Mounting Method
terminal single group
-
Winding Operating Current
9.0 amperes ac nominal single component single primary
-
Special Features
one primary winding and five secondary windings
-
Test Data Document
26916-050-005338 drawing
-
Reliability Indicator
not established
-
Winding Shielding Method
internally shielded single component
-
Body Length
2.110 inches minimum and 2.120 inches maximum
-
Overall Diameter
2.500 inches maximum
-
Maximum Operating Temp
155.0 deg celsius
-
Winding Function And Quantity
1 primary single component and 5 secondary
-
Winding Tap Location
multiple taps w/o center tap single component 1st secondary
-
Winding Tap Location
multiple taps w/o center tap single component 2nd secondary
-
Winding Tap Location
multiple taps w/o center tap single component 4th secondary
-
Winding Power Rating
1.8 k1lovolt-amperes single component single primary
-
Winding Operating Voltage
200.00 ac volts nominal single component single primary
-
Terminal Type And Quantity
34 pin
Related Parts by Category