Technical Characteristics
- 
                                    Overall Height0.965 inches maximum 
- 
                                    Vibration Resistance Range In Hertz20.0/ 2000.0 
- 
                                    Operating Temp Range-54.0/+125.0 deg celsius 
- 
                                    Source Impedance Rating Per Function50.0 ohms 2nd radio interference . 
- 
                                    Source Impedance Rating Per Function50.0 ohms 5th radio interference . 
- 
                                    Load Impedance Per Function50.0 ohms 1st radio interference . 
- 
                                    Load Impedance Per Function50.0 ohms 2nd radio interference . 
- 
                                    Load Impedance Per Function50.0 ohms 6th radio interference . 
- 
                                    Power Line Frequency Rating Per Function In Hertz400.0 1st radio interference . 
- 
                                    Power Line Frequency Rating Per Function In Hertz400.0 2nd radio interference . 
- 
                                    Power Line Frequency Rating Per Function In Hertz400.0 3rd radio interference . 
- 
                                    Power Line Frequency Rating Per Function In Hertz400.0 4th radio interference . 
- 
                                    Power Line Frequency Rating Per Function In Hertz400.0 5th radio interference . 
- 
                                    Operating Current Rating Per Function In Amps3.0 1st radio interference . 
- 
                                    Operating Current Rating Per Function In Amps3.0 4th radio interference . 
- 
                                    Operating Current Rating Per Function In Amps3.0 5th radio interference . 
- 
                                    Principal Circuitry Type Per Functioninductance-capacitance 2nd radio interference 
- 
                                    Principal Circuitry Type Per Functioninductance-capacitance 6th radio interference 
- 
                                    Functional Terminal Type And Quantity1 connector, plug input . 
- 
                                    Operating Voltage Rating And Type Per Function125.0 volts ac 2nd radio interference and 200.0 volts dc 2nd radio interference 
- 
                                    Operating Voltage Rating And Type Per Function125.0 volts ac 5th radio interference and 200.0 volts dc 5th radio interference 
- 
                                    Operating Voltage Rating And Type Per Function125.0 volts ac 6th radio interference and 200.0 volts dc 6th radio interference 
- 
                                    Operating Voltage Rating And Type Per Function50.0 volts ac 1st radio interference and 100.0 volts dc 1st radio interference . 
- 
                                    Special Features50 functions; 48 filtered contacts and 2 power contacts 
- 
                                    Style Designator45 filter connector 
- 
                                    Principal Circuitry Type Per Functioninductance-capacitance 3rd radio interference 
- 
                                    Principal Circuitry Type Per Functioninductance-capacitance 4th radio interference 
- 
                                    Principal Circuitry Type Per Functioninductance-capacitance 5th radio interference 
- 
                                    Inclosure Typeencased 
- 
                                    Mounting Facility Type And Quantity2 unthreaded hole 
- 
                                    Functional Terminal Type And Quantity50 friction w/grounding strap and pin output . 
- 
                                    ~1. 
- 
                                    Operating Voltage Rating And Type Per Function125.0 volts ac 3rd radio interference and 200.0 volts dc 3rd radio interference 
- 
                                    Operating Voltage Rating And Type Per Function50.0 volts ac 4th radio interference and 100.0 volts dc 4th radio interference . 
- 
                                    Overall Length2.620 inches minimum and 2.658 inches maximum 
- 
                                    Overall Width0.590 inches minimum and 0.720 inches maximum 
- 
                                    Unthreaded Mounting Hole Diameter0.115 inches minimum and 0.125 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.401 inches minimum and 2.411 inches maximum 
- 
                                    Source Impedance Rating Per Function50.0 ohms 1st radio interference . 
- 
                                    Source Impedance Rating Per Function50.0 ohms 3rd radio interference . 
- 
                                    Source Impedance Rating Per Function50.0 ohms 4th radio interference . 
- 
                                    Source Impedance Rating Per Function50.0 ohms 6th radio interference . 
- 
                                    Load Impedance Per Function50.0 ohms 3rd radio interference . 
- 
                                    Load Impedance Per Function50.0 ohms 4th radio interference . 
- 
                                    Load Impedance Per Function50.0 ohms 5th radio interference . 
- 
                                    Power Line Frequency Rating Per Function In Hertz400.0 6th radio interference . 
- 
                                    Operating Current Rating Per Function In Amps3.0 2nd radio interference . 
- 
                                    Operating Current Rating Per Function In Amps3.0 3rd radio interference . 
- 
                                    Operating Current Rating Per Function In Amps3.0 6th radio interference . 
- 
                                    Principal Circuitry Type Per Functioninductance-capacitance 1st radio interference 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    