MIL-C-55629/7

Circuit Breakers

CIRCUIT BREAKER

MIL-C-55629/7

5925-01-302-6504

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    12a single pole type

  • Body Length

    1.969 inches minimum and 2.031 inches maximum

  • Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.529 inches minimum and 1.591 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct single location and 8.000 maximum at 200 pct

  • Test Data Document

    81349-mil-c-55629 specification

  • Specification/Standard Data

    81349-mil-c-55629/7 government specification

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.629 inches minimum and 1.691 inches maximum

  • Boss Height

    0.099 inches minimum and 0.161 inches maximum

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole one

  • Inclosure Protection Type For Which Designed

    dustproof

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...