TDH8050-5002
Relays and Solenoids
RELAY,ELECTROMAGNETIC
TDH8050-5002
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Voltage Rating And Type At Specified Temp
30.0 volts dc 25 deg celsius single winding
-
Duty Type
continuous
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
-
Mounting Facility Pattern
triangle single mounting facility
-
Time Delay
50.00 seconds nominal fixed operate time
-
Nominal Operating Current Rating And Type
150.0 milliamperes dc single winding
-
Mounting Slot Width
0.140 inches minimum single mounting facility and 0.160 inches maximum single mounting facility
-
Terminal Type And Quantity
8 pin all functions
-
Main Contact Maximum Voltage Rating In Volts
200.0 ac and 28.0 dc
-
Purpose For Which Designed
general
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.615 inches minimum single mounting facility and 0.635 inches maximum single mounting facility
-
End Item Identification
platform cont
-
Coil Quantity
1
-
Overall Height
1.260 inches minimum and 1.290 inches maximum
-
Overall Length
1.708 inches minimum and 1.718 inches maximum
-
Overall Width
1.015 inches minimum and 1.025 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
1.413 inches minimum single mounting facility and 1.433 inches maximum single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes ac inductive load and 8.0 amperes dc inductive load
-
Fragility Factor
moderately rugged
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
-
Storage Type
general purpose warehouse
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Environmental Protection
hermetic
-
Arc Quenching Method
air
-
Cubic Measure
2.272 cubic inches
-
Winding Quantity
1
-
Mounting Facility Type And Quantity
3 slotted hole single mounting facility
-
Case Material
metal
-
Features Provided
polarized
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods