260-0952-110
Circuit Breakers
CIRCUIT BREAKER
260-0952-110
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
6 threaded stud
-
Mounting Surface To Terminal End Distance
0.630 inches maximum
-
Body Style
single pole type
-
Boss Height
0.700 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Reset Method
manual
-
Trip Release Duty Cycle
continuous all locations
-
Trip Release Characteristic
time delay all locations
-
Body Width
2.280 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.750 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
50.000 maximum at 225 pct single location
-
Circuit Protection Type
overcurrent all locations
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations
-
Ultimate Trip Time Per Pole In Seconds
5.000 maximum all locations
-
Pole Quantity
3
-
Internal Trip Release Configuration
series/relay trip single location
-
Nominal Thread Size
0.138 inches
-
Maximum Continuous Load Current Rating Per Pole
3.5 amperes dc all locations
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
125.0 ac nominal all locations
-
Mounting Facility Type And Quantity
6 threaded stud
-
Thread Quantity Per Inch
32
-
Frequency In Hertz
60.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Body Length
2.530 inches maximum
-
Thread Series Designator
unc
Related Parts by Category
Related Parts by Manufacturer