Technical Characteristics
-
Body Style
8c multipole-multiple actuator type
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
3.480 inches minimum and 3.614 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.730 inches minimum and 2.770 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.006 inches minimum and 1.046 inches maximum
-
Mounting Surface To Terminal End Distance
3.580 inches nominal
-
Mounting Facility Type And Quantity
8 threaded hole
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
60.0 amperes ac all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac third location
-
Trip Release Method
magnetic-hydraulic all locations
-
Trip Release Characteristic
time delay fourth location
-
Body Length
5.105 inches minimum and 5.145 inches maximum
-
Body Width
4.124 inches minimum and 4.164 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
1.006 inches minimum and 1.046 inches maximum
-
Boss Height
0.199 inches minimum and 0.239 inches maximum
-
Pole Quantity
4
-
Arc Quenching Method
magnetic blowout
-
Special Handling Feature
magnetic
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac first location
-
Frequency In Hertz
400.0 second location
-
Frequency In Hertz
440.0 first location
-
Thread Series Designator
unc
-
Terminal Type And Quantity
10 threaded stud
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
4 toggle
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Internal Trip Release Configuration
relay trip first location
-
Internal Trip Release Configuration
series trip second location
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct second location and 10.000 maximum at 200 pct
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct third location and 10.000 maximum at 200 pct
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac fourth location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Characteristic
instantaneous first location
-
Trip Release Characteristic
time delay second location
-
Trip Release Characteristic
time delay third location
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
Internal Trip Release Configuration
series trip fourth location
-
Internal Trip Release Configuration
series trip third location
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct fourth location and 10.000 maximum at 200 pct
-
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
-
Frequency In Hertz
400.0 fourth location
-
Frequency In Hertz
400.0 third location