MS27401-44X
Relays and Solenoids
RELAY,ELECTROMAGNETIC
MS27401-44X
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Specification/Standard Data
81349--83536/10 government specification
-
Nominal Operating Current Rating And Type
110.0 milliamperes dc single winding
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
-
Overall Height
1.010 inches maximum
-
Storage Type
general purpose warehouse
-
Criticality Code Justification
feat
-
Time Delay
0.01 seconds maximum fixed operate and release time
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Cubic Measure
0.543 cubic inches
-
Environmental Protection
hermetic
-
Mounting Slot Width
0.150 inches nominal single mounting facility
-
Winding Dc Resistance Rating
320.0 ohms nominal single winding
-
Arc Quenching Method
air
-
Mounting Facility Type And Quantity
2 slotted hole single mounting facility
-
Winding Quantity
1
-
Case Material
metal
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
-
Overall Length
1.025 inches maximum
-
Overall Width
0.525 inches maximum
-
Terminal Type And Quantity
8 pin all functions
-
Main Contact Maximum Voltage Rating In Volts
200.0 ac and 28.0 dc
-
Purpose For Which Designed
general
-
Test Data Document
81349-mil-r-83536 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performanc
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
-
Coil Quantity
1
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.421 inches nominal single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes ac inductive load and 8.0 amperes dc inductive load
-
Duty Type
continuous
-
Mounting Facility Pattern
in-line single mounting facility
-
Special Features
failure rate: 1.0 percent per 10,000 cycles
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods