12-771842-20
Circuit Breakers
CIRCUIT BREAKER
12-771842-20
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Trip Release Characteristic
instantaneous all locations
 - 
                                    
Pole Quantity
3
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Body Style
rectangular dimensional envelope
 - 
                                    
Overall Length
9.120 inches nominal
 - 
                                    
Reset Method
manual
 - 
                                    
Features Provided
adjustable trip release
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Overall Width
8.240 inches minimum and 8.250 inches maximum
 - 
                                    
Switch Terminal Type
wire lead
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations and 250.0 dc all locations
 - 
                                    
Auxiliary Switch Function And Quantity
4 alarm
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
 - 
                                    
Trip Release Method
thermal-magnetic all locations
 - 
                                    
Switch Contact Arrangement
single pole, double throw
 - 
                                    
Trip Release Ambient Temp Rating
50.0 deg celsius nominal all locations
 - 
                                    
Overall Height
5.380 inches maximum
 - 
                                    
Switch Current Rating And Type In Amps
6.0 ac and 0.250 dc
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
22000.0 ac all locations and 10000.0 dc all locations
 - 
                                    
Terminal Type And Quantity
6 compression
 - 
                                    
Switch Location And Position Designation
external at pole three
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Mounting Facility Type And Quantity
4 unthreaded hole
 - 
                                    
Special Features
48 vdc shunt trip with wire leads installed on right side of circuit breaker; 120 vac motor operator mounted on front of circuit breaker,5.750 inch lg,3.230 inch w,10.120 inch h
 - 
                                    
Unthreaded Mounting Hole Diameter
0.310 inches nominal
 - 
                                    
Inclosure Protection Type For Which Designed
general purpose
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
400.0 amperes ac all locations and 400.0 amperes dc all locations
 - 
                                    
Adjustable Trip Setting Current Range Per Pole In Amps
+1200.0/+4000.0 ac all locations and +1200.0/+4000.0 dc all locations
 - 
                                    
Switch Voltage Rating And Type In Volts
240.0 ac and 250.0 dc
 - 
                                    
Case Material
plastic
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    