NZM6B-63/ZM6-12-80-OBI-CNA/CL6

Circuit Breakers

CIRCUIT BREAKER

NZM6B-63/ZM6-12-80-OBI-CNA/CL6

5925-01-317-0487

5925 - Circuit Breakers

Klockner-Moeller Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 terminal

  • Reset Method

    manual

  • Overall Width

    110.0 millimeters nominal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Features Provided

    adjustable trip release and current limiter

  • Circuit Protection Type

    undervoltage all locations

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    210.0 millimeters nominal

  • Overall Length

    210.0 millimeters nominal

  • Boss Height

    16.0 millimeters nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Case Material

    plastic

  • Body Width

    252.0 millimeters nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +40.0/+80.0 ac all locations

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 rotary

  • Maximum Continuous Load Current Rating Per Pole

    12.0 amperes ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Overall Height

    180.0 millimeters nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    95.0 millimeters nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    95.0 millimeters nominal

  • Center To Center Distance Between Terminals Parallel To Length

    252.0 millimeters nominal

  • Actuator Function

    trip-reset

  • Body Length

    280.5 millimeters nominal

  • Body Height

    110.0 millimeters nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...