AP12-1-65F-752

Circuit Breakers

CIRCUIT BREAKER

AP12-1-65F-752

5925-01-318-5929

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Nonturn Device Radius

    0.594 inches minimum and 0.656 inches maximum

  • Nonturn Device Length

    0.099 inches minimum and 0.161 inches maximum

  • Nonturn Device Diameter

    0.145 inches minimum and 0.149 inches maximum

  • Fragility Factor

    moderately rugged

  • Arc Quenching Method

    magnetic blowout

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    between pole one and two

  • Nominal Thread Size

    0.375 inches

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Case Material

    metal

  • Special Features

    inertial delay included

  • Frequency In Hertz

    50.0 or 60.0

  • Thread Series Designator

    unef

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Body Style

    1b multipole-single actuator type

  • Bushing Length

    0.380 inches maximum

  • Body Length

    1.562 inches maximum

  • Body Width

    1.281 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and 0.906 inches maximum

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Mounting Surface To Terminal End Distance

    0.780 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.450 minimum at 200 pct and 8.500 maximum at 200 pct all locations

  • Terminal Type And Quantity

    4 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...