M55629/22UPUPUP

Circuit Breakers

CIRCUIT BREAKER

M55629/22UPUPUP

5925-01-318-9548

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Specification/Standard Data

    81349-mil-c-55629/22 government specification

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Nonturn Device Radius

    0.641 inches minimum and 0.671 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.100 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Thread Series Designator

    unef

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Bushing Length

    0.594 inches minimum and 0.656 inches maximum

  • Trip Release Method

    magnetic all locations

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    1.499 inches minimum and 1.561 inches maximum

  • Nonturn Device Location

    at 12 oclock and at 3 oclock and at 9 oclock

  • Case Material

    metal

  • Body Width

    2.265 inches maximum

  • Body Length

    1.969 inches minimum and 2.031 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Terminal Type And Quantity

    6 tab w/screw

  • Nonturn Device Length

    0.115 inches minimum and 0.145 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Center To Center Distance Between Terminals Parallel To Width

    0.719 inches minimum and 0.781 inches maximum

  • ~1

    data on certain environmental and performanc

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Switch Current Rating And Type In Amps

    10.0 ac and 1.0 dc

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...