Technical Characteristics
- 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Trip Release Characteristic
instantaneous all locations
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Pole Quantity
2
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Actuator Position Designation
at each pole
 - 
                                    
Reset Method
manual
 - 
                                    
Terminal Type And Quantity
6 tab, solder lug
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Mounting Surface To Terminal End Distance
1.898 inches minimum and 1.962 inches maximum
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.718 inches minimum and 0.782 inches maximum
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
0.718 inches minimum and 0.782 inches maximum
 - 
                                    
Mounting Facility Type And Quantity
4 threaded hole
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Trip Release Method
magnetic all locations
 - 
                                    
Body Style
multipole-multiple actuator type
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
 - 
                                    
Internal Trip Release Configuration
series trip first location
 - 
                                    
Internal Trip Release Configuration
series/relay trip second location
 - 
                                    
Body Length
1.968 inches minimum and 2.032 inches maximum
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
40.0 amperes ac all locations
 - 
                                    
Inclosure Protection Type For Which Designed
dustproof and fungus proof
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
1.528 inches minimum and 1.592 inches maximum
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Auxiliary Trip Coil Voltage Type And Rating In Volts
48.0 dc nominal second location
 - 
                                    
Body Width
1.468 inches minimum and 1.532 inches maximum
 - 
                                    
Boss Height
0.098 inches minimum and 0.162 inches maximum
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
 - 
                                    
Manual Actuator Type And Quantity
2 toggle
 - 
                                    
Trip Release Duty Cycle
continuous second location
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.628 inches minimum and 1.692 inches maximum
 - 
                                    
External Actuator Linkage Arrangement
one and two linked
 - 
                                    
Case Material
plastic
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    