WF1814/09-005
Fuses, Arrestors, Absorbers, and Protectors
FUSE,CARTRIDGE
WF1814/09-005
5920 - Fuses, Arrestors, Absorbers, and Protectors
FUSE,CARTRIDGE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Features Provided
nonrenewable fusible element
-
Circuit Over-Current Interruption Delay Time In Seconds
600.0 200 pct of current rating
-
Circuit Over-Current Interruption Type
time delay
-
Mounting Slot Width
0.401 inches minimum and 0.411 inches maximum
-
Test Data Document
81348-w-f-1814 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performance r
-
Terminal Width
1.590 inches minimum and 1.660 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
5.190 inches minimum and 5.310 inches maximum
-
Short-Circuit/Interrupt Current Rating In Amps
200000.0
-
Specification/Standard Data
81348-w-f-1814/9 government specification
-
Overall Diameter
2.120 inches maximum
-
Terminal Thickness
0.247 inches minimum and 0.253 inches maximum
-
Body Style
hole type
-
Continuous Current Rating In Amps
400.000
-
Overall Length
7.030 inches minimum and 7.210 inches maximum
-
Terminal Material
copper alloy or brass or copper
-
Interruption Indicator Method
opaque body
-
Maximum Voltage Rating In Volts
600.0 ac and 600.0 dc
-
Case Material
ceramic