SI8P52-07W12-10PN

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

SI8P52-07W12-10PN

5915-01-329-7737

5915 - Filters and Networks

Souriau Inc

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Voltage Drop Per Function

    8.0 volts dc 3rd radio interference

  • Output Terminal Identification

    mil-c-26482

  • Maximum Voltage Drop Per Function

    8.0 volts dc 4th radio interference

  • Full Load Minimum Insertion Loss At Specified Frequency In Decibels

    10.0 and 3.0 and 10.0 and 10.0 and 50.0

  • Maximum Voltage Drop Per Function

    8.0 volts dc 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Input Terminal Identification

    mil-c-26482

  • Body Surface Treatment

    cadmium

  • Maximum Voltage Drop Per Function

    8.0 volts dc 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Maximum Dielectric Withstanding Ac Rms Voltage

    1.2 kilovolts at sea level

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Maximum Temp Rise

    25.0 deg celsius

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference

  • Output Terminal Manufacturer Code

    59610

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 2nd radio interference 2nd function and 250.0 volts ac 5th radio interference 5th function and 250.0 volts ac 1st radio interference 1st function and 250.0 volts ac 6th radio interference 6th function and 250.0 volts ac 3rd radio

  • Maximum Voltage Drop Per Function

    2.5 volts ac 2nd radio interference and 2.5 volts ac 5th radio interference and 2.5 volts ac 3rd radio interference and 2.5 volts ac 4th radio interference and 2.5 volts ac 1st radio interference and 2.5 volts ac 6th radio interference and 8.0 volts dc

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 6th radio interference 6th function

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 5th radio interference 5th function

  • Full Load Insertion Loss Frequencies In Megahertz

    10.0 and 100.0 and 0.1 and 0.0 and 1.0 and 1000.0

  • Unthreaded Mounting Hole Diameter

    0.125 inches nominal

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 4th radio interference 4th function

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 3rd radio interference 3rd function

  • Precious Material

    gold

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 2nd radio interference 2nd function

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Overall Width

    1.710 inches nominal

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 6th radio interference

  • Input Terminal Manufacturer Code

    59610

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Overall Length

    2.187 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • ~1

    2nd radio interference

  • ~1

    interference 3rd function and 250.0 volts ac 4th radio

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Precious Material And Location

    contact surfaces gold

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.271 inches nominal

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Functional Terminal Type And Quantity

    10 friction w/grounding strap and pin input-output

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.271 inches nominal

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Features Provided

    moisture resistant and shock resistant

  • Maximum Voltage Drop Per Function

    8.0 volts dc 1st radio interference

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference

  • Overall Height

    1.710 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Body Material

    aluminum

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Special Features

    ten filtered functions w n-type insert position

  • Maximum Dielectric Withstanding Dc Voltage

    1.2 kilovolts at sea level

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Style Designator

    filter connector

  • Full Load Minimum Insertion Loss At Specified Frequency In Decibels

    50.0 and hermetically sealed

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...