7274-44-1/2

Circuit Breakers

CIRCUIT BREAKER

7274-44-1/2

5925-01-330-9216

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.692 inches minimum and 1.722 inches maximum

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Bushing Length

    0.235 inches minimum and 0.250 inches maximum

  • Body Width

    0.531 inches minimum and 0.593 inches maximum

  • Body Length

    0.719 inches minimum and 0.781 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac single location and 2000.0 dc single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Nominal Thread Size

    0.468 inches

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.672 inches minimum and 0.734 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes ac single location and 500.0 milliamperes dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...