M55629/20NL

Circuit Breakers

CIRCUIT BREAKER

M55629/20NL

5925-01-331-4063

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    2a single pole type

  • Bushing Length

    0.594 inches minimum and 0.656 inches maximum

  • Body Length

    1.969 inches minimum and 2.031 inches maximum

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Nonturn Device Radius

    0.610 inches minimum and 0.640 inches maximum

  • Nonturn Device Length

    0.115 inches minimum and 0.145 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct single location and 1.500 maximum at 200 pct

  • Switch Current Rating And Type In Amps

    10.0 ac and 1.0 dc

  • Test Data Document

    81349-mil-c-55629 specification

  • Thread Series Designator

    un

  • Specification/Standard Data

    81349-mil-c-55629/20 government specification

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    1.499 inches minimum and 1.561 inches maximum

  • Nonturn Device Location

    at 12 oclock

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Features Provided

    high inrush protection

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.500 inches

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Switch Terminal Type

    tab, solder lug

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Terminal Type And Quantity

    2 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...