TKJL110709-52

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

TKJL110709-52

5915-01-333-8897

5915 - Filters and Networks

Itt Cannon Electric

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Unthreaded Mounting Hole Diameter

    0.142 inches minimum and 0.157 inches maximum

  • Special Features

    thirty five filtered functions

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 6th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 4th radio interference 4th function and 200.0 volts dc 4th radio interference 4th function

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Overall Height

    1.708 inches maximum

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference

  • Inclosure Type

    encased

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference

  • Maximum Temp Rise

    25.0 deg celsius

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Functional Terminal Type And Quantity

    35 friction w/grounding strap and pin input-output

  • Body Surface Treatment

    cadmium

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 6th radio interference 6th function and 200.0 volts dc 6th radio interference 6th function

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Overall Length

    1.903 inches maximum

  • Overall Width

    1.708 inches maximum

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 3rd radio interference 3rd function and 200.0 volts dc 3rd radio interference 3rd function

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Body Material

    aluminum

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 1st radio interference 1st function and 200.0 volts dc 1st radio interference 1st function

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Maximum Dielectric Withstanding Dc Voltage

    500.0 volts at sea level

  • Style Designator

    filter connector

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 2nd radio interference 2nd function and 200.0 volts dc 2nd radio interference 2nd function

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 5th radio interference 5th function and 200.0 volts dc 5th radio interference 5th function

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...